Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 75
Filter
1.
Arq. bras. oftalmol ; 87(4): e2022, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1520232

ABSTRACT

ABSTRACT Purpose: To compare the differences between the apparent and actual chord μ. Methods: In this prospective, comparative, non-randomized, and non-interventional study, imaging examinations using Pentacam and the HD Analyzer were performed in the same room under the same scotopic conditions. The inclusion criteria were patients aged 21-71 years, able to provide informed consent, myopia up to 4D, and anterior topographic astigmatism up to 1D. Patients using contact lenses, those with previous eye diseases or surgeries, corneal opacities, corneal tomographic changes, or suspected keratoconus were excluded. Results: Altogether, 116 eyes of 58 patients were analyzed. The patients' mean age was 30.69 (±7.85) years. In the correlation analyses, Pearson's correlation coefficient of 0.647 indicates a moderate positive linear relationship between apparent and actual chord μ. The mean actual and apparent chord μ were 226.21 ± 128.53 and 278.66 ± 123.90 μm, respectively, with a mean difference of 52.45 μm (p=0.01). The analysis of mean pupillary diameter resulted in 5.76 mm using the HD Analyzer and 3.31 mm using the Pentacam. Conclusions: We found a correlation between the two measurement devices, and even though we found considerable differences, both can be used in daily practice. Given their differences, we should respect their peculiarities as well.


RESUMO Objetivo: Comparar as diferenças entre a chord aparente μ e o chord real μ. Métodos: Estudo prospectivo, comparativo, não randomizado e não intervencionista. Os exames de imagem (Pentacam e HD Analyzer) foram realizados na mesma sala e nas mesmas condições escotópicas. Os critérios de inclusão foram idade de 21 a 71 anos; compreensão do termo de consentimento; miopia até 4D e astigmatismo topográfico anterior até 1D. Os critérios de exclusão foram usuários de lentes de contato; pacientes com doenças oculares prévias ou cirurgias; opacidades da córnea; a presença de alterações tomográficas da córnea ou suspeita de ceratocone. Resultados: Em nosso estudo foram analisados 116 olhos de 58 pacientes. A média de idade foi de 30,69 anos (± 7,85). Análises de correlação foram desenvolvidas e o coeficiente de correlação de Pearson (0,647) indica uma relação linear positiva moderada entre as variáveis. A média do chord μ real foi 226,21 ± 128,53 μm e a média do chord μ média foi 278,66 ± 123,90 μm, com diferença média de 52,45 μm (p=0,01). A análise do diâmetro pupilar médio apresentou: 5,76mm no HD Analyzer e 3,31mm no Pentacam. Conclusões: Entendemos a existência de uma diferença significativa entre os métodos e assim a medida de ambos os dispositivos com base em princípios diferentes devemos respeitar suas peculiaridades. Como encontramos correlação entre as duas medidas, acreditamos que ambas podem ser utilizadas na prática diária.

2.
Arq. bras. oftalmol ; 81(5): 393-400, Sept.-Oct. 2018. tab, graf
Article in English | LILACS | ID: biblio-950484

ABSTRACT

ABSTRACT Purpose: The aim of this study was to compare the corneal cell viability and thickness of LASIK flaps created by 3 femtosecond lasers in eye-bank human corneas. Methods: Forty-five eye-bank human sclerocorneal buttons (15 corneas in each group) were examined after the creation of 120 mm-thick laser-assisted keratomileusis (LASIK) flaps with 150kHz iFS In­traLase™ (IL), Z6 Femto LDV™ (LDV), or 200kHz Wavelight™ FS200 (FS200). The thickness of the flaps was measured using anterior segment optical coherence tomography (AS-OCT; Visante™). Cell viability was blindly evaluated with immunohistochemistry for keratocyte apoptosis using anti-caspase 3 antibodies. Results: The standard deviation from the intended flap thickness was less than 10 mm in all the groups. There was a statistically significant difference in corneas treated with LDV and IL with regard to the flap thickness horizontally at +3.00 mm (p=0.0124), -0.5 mm (p=0.0082), and -1.00 mm (p=0.0425) from the corneal vertex and +0.5 mm from the flap edge (p=0.0240), and those treated with LDV and FS200 with regard to the flap thickness horizontally at -0.5 mm from the corneal vertex (p=0.0082). The mean keratocyte apoptosis numbers were 13.09 ± 1.10, 15.59 ± 3.28, and 17.72 ± 1.49 in corneas treated with IL, FS200, and LDV, respectively (p<0.001). Conclusion: All 3 assessed femtosecond lasers provided predictable LASIK flap thickness. The mean stromal keratocyte apoptosis number was low in all groups.


RESUMO Objetivos: Comparar a viabilidade celular e a espessura do disco de LASIK confeccionado por três laseres de femtosegundo, em córneas humanas de banco de olhos. Métodos: Quarenta e cinco botões córneo-esclerais humanos de banco de olhos (15 córneas em cada grupo) foram examinados, após a criação de disco de LASIK com 120 mm de espessura, utilizando-se o iFS IntraLase® 150kHz (IL), o Femto LDV® Z6 (LDV), ou o Wavelight® FS200 200kHz (FS200). Tomografia de coerência óptica do seguimento anterior (OCT Visante®) foi usada para medir a espessura dos discos. A viabilidade celular foi avaliada por meio de imuno-histoquímica para apoptose dos ceratócitos, com anti-caspase 3. Resultados: O desvio padrão da espessura planejada do disco foi inferior a 10 mm em todos os grupos. Houve diferença estatisticamente significante da espessura do disco horizontalmente a +3,00 mm (p=0,0124), -0,5 mm (p=0,0082) e -1,00 mm (p=0,0425), a partir do vértice corneal, e a +0,5 mm (p=0,0240), a partir da borda do disco, em córneas tratadas por LDV e IL, e horizontalmente a -0,5 mm a partir do vértice corneal, entre LDV e FS200 (p=0,0082). A média de apoptose dos ceratócitos foi (13,09 ± 1,10), (15,59 ± 3,28) e (17,72 ± 1,49), em córneas tratadas pelo IL, FS200 e LDV, respectivamente (p<0,001). Conclusão: Todos os três laseres de femtosegundo estudados produziram disco de LASIK com predictibilidade de espessura. A média de apoptose dos ceratócitos foi baixa em todos os grupos.


Subject(s)
Humans , Surgical Flaps , Cornea/anatomy & histology , Immunohistochemistry , Cornea/surgery , Keratomileusis, Laser In Situ , Tomography, Optical Coherence , Eye Banks
3.
Arq. bras. oftalmol ; 81(3): 183-187, May-June 2018. tab
Article in English | LILACS | ID: biblio-950460

ABSTRACT

ABSTRACT Purpose: This report describes the use of Descemet membrane endothelial keratoplasty for the management of endothelial decompensation after multifocal intraocular lens implantation. Methods: In this retrospective study, we reviewed and assessed the surgical outcomes of 9 patients (9 eyes) who underwent Descemet membrane endothelial keratoplasty after multifocal intraocular lens implantation. Results: Corneal edema occurred due to Fuchs endothelial corneal dystrophy (n=3), pseudophakic bullous keratopathy (n=3), Descemet's membrane detachment (n=2), and toxic anterior segment syndrome (n=1). The Descemet membrane endothelial keratoplasty surgeries were uneventful in all eyes, but rebubbling procedures were necessary in 2 eyes. One month after the surgery, all the corneas were clear. After 6 months, excluding 1 eye with amblyopia, the mean distance corrected visual acuity was 0.10 logMAR, with all eyes achieving 0.18 logMAR or better. Conclusions: This is the first report of Descemet membrane endothelial keratoplasty after multifocal intraocular lens implantation, and it suggests that good results can be achieved without multifocal intraocular lens exchange.


RESUMO Objetivo: Descrever o uso da ceratoplastia endotelial da membrana de Descemet para manejar descompensação endotelial após implante de lente intraocular multifocal. Métodos: Neste estudo retrospectivo, foram revisados e avaliados os resultados cirúrgicos de 9 olhos de 9 pacientes que foram submetidos a ceratoplastia endotelial da membrana de Descemet para manejar descompensação endotelial após implante de lente intraocular multifocal. Resultados: Descompensação endotelial ocorreu por distrofia endotelial de Fuchs (n=3), ceratopatia bolhosa do pseudofácico (n=3), descolamento da membrana de Descemet (n=2) e síndrome tóxica do segmento anterior (n=1). No ato per operatório de todos os olhos não houve intercorrência, com injeção de ar sendo necessário em dois olhos no pós-operatório por descolamento parcial do enxerto. Um mês após a cirurgia, todas as córneas estavam claras. Após seis meses, excluindo um olho com ambliopia, a acuidade visual média corrigida para longe foi de 0,10 logMAR, com todos os olhos atingindo 0,18 logMAR ou melhor. Conclusões: Este é o primeiro relato de ceratoplastia endotelial da membrana de Descemet após implante de lente intraocular multifocal, sugerindo que bons resultados podem ser alcançados sem a troca da lente intraocular multifocal.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Aged, 80 and over , Pseudophakia/surgery , Descemet Stripping Endothelial Keratoplasty/methods , Retrospective Studies , Treatment Outcome , Pseudophakia/etiology , Lens Implantation, Intraocular/adverse effects
4.
Arq. bras. oftalmol ; 81(1): 66-69, Jan.-Feb. 2018. graf
Article in English | LILACS | ID: biblio-888176

ABSTRACT

ABSTRACT We report intraoperative finding of Granular Corneal Dystrophy Type-1 (GCD1) deposits after stromal pneumodissection in deep anterior lamellar keratoplasty (DALK) in a 61-year-old female. Pneumodissection was performed from the center to the periphery of the cornea, characterizing a big bubble type 1 technique which dissects the deep stroma from the predescemetic layer. After stromal removal, persistence of whitish deposits inside the predescemetic layer was noted. During post-operative evaluation, anterior biomicroscopy and anterior segment optical coherence tomography showed granular opacities between the patient's Descemet's membrane and the donor cornea, suggesting possible involvement of the predescemetic layer in GCD1. This may require the surgeon's attention to choose between DALK keratoplasty or penetrating keratoplasty.


RESUMO Relatamos o achado intraoperatório de persistência dos depósitos de Distrofia Granular Tipo 1 (GCD1) após pneumodissecção estromal no transplante de córnea lamelar anterior profundo (DALK) em uma mulher de 61 anos. A pneumodissecção começou a partir do centro para a periferia da córnea, caracterizando uma big bubble tipo 1, que disseca o estroma profundo da camada pré-Descemet. Após a remoção do estroma, notamos a persistência de depósitos esbranquiçados no interior da camada pré-Descemet. Na avaliação pós-operatória, a biomicroscopia anterior e a tomografia de coerência óptica do segmento anterior evidenciaram opacidades granulares entre a membrana de Descemet e a córnea doadora, sugerindo o possível envolvimento da camada pré-Descemet na GCD1, o que pode chamar atenção do cirurgião para decidir entre manter o DALK ou converter para transplante penetrante.


Subject(s)
Humans , Female , Middle Aged , Corneal Dystrophies, Hereditary/surgery , Corneal Transplantation/methods , Descemet Membrane/surgery , Corneal Dystrophies, Hereditary/pathology , Corneal Dystrophies, Hereditary/diagnostic imaging , Treatment Outcome , Corneal Stroma/surgery , Corneal Stroma/pathology , Corneal Stroma/diagnostic imaging , Tomography, Optical Coherence , Descemet Membrane/pathology , Descemet Membrane/diagnostic imaging , Slit Lamp Microscopy
5.
Rev. bras. oftalmol ; 74(5): 292-296, set.-out. 2015. tab, ilus
Article in English | LILACS | ID: lil-757454

ABSTRACT

Objective:To evaluate the introduction of the femtosecond laser (FSL) to perform the key steps of the traditional cataract surgery process and the operational difficulties and safety of this new technology during routine use in an operating room in Brazil.MethodsA retrospective study was conducted using the first cases operated on at a single center using the laser platform LenSx/Alcon with a soft contact lens patient interface.All patients underwent a detailed preoperative assessment.The anterior capsulotomy, nuclear fragmentation, and corneal incisions were created with the FSL; then, the surgery was completed following the standard phacoemulsification procedure. The main outcome measurements were difficulties and complications related to the learning curve and an analysis of postoperative uncorrected distance visual acuity (UDVA).Results:Of 31 patients (40 eyes), 9 patients had FSL cataract surgery in both eyes.The mean age was 64 ± 12 years (ranging from 42 to 82), the mean cataract nuclear sclerosis was grading 2 ± 0.6 (ranging from 1 to 4), and the preoperative mean UDVA in logMAR was 0.4 ± 0.2 (ranging from 0.1 to 1.3). Anterior capsulotomy was complete in all patients, and scissors were not needed to cut off any intact portion. The postoperative corneal incisions were not completely linear and showed some irregularities. Laser phaco-fragmentation was effective, with the division of the nucleus into smaller segments easily performed before phacoemulsification.After 1 month, the postoperative mean UDVA in logMAR was 0.1 ± 0.1 (ranging from 0.0 to 0.4) (P < 0.0001).Conclusion:With increasing surgical cases and experience, the phacoemulsification steps are performed precisely and effectively with FSL pretreatment, resulting in a safe learning curve.


Objetivo:Avaliar a introdução do laser de femtossegundo (FSL) para realizar etapas fundamentais da cirurgia de catarata tradicional e as dificuldades e segurança desta nova tecnologia na rotina de um centro cirúrgico no Brasil.Métodos:Um estudo retrospectivo foi realizado com os primeiros casos operados em um único centro usando a plataforma de laser LenSx/Alcon, sendo utilizado lentes de contato gelatinosa na interface do paciente. Todos os pacientes foram submetidos a uma avaliação pré-operatória detalhada. Capsulotomia anterior, fragmentação nuclear e incisões na córnea foram criados com a FSL, em seguida, a cirurgia foi concluída com procedimento de facoemulsificação padrão. As principais medidas de desfecho foram dificuldades e complicações relacionadas à curva de aprendizado e análise da acuidade visual pós-operatória não corrigida à distância (UDVA).Resultados:Dos 31 pacientes (40 olhos), 9 realizaram cirurgia de catarata em ambos os olhos com FSL. A média de idade foi de 64 ± 12 anos (variando de 42 a 82), a média de classificação da catarata através da esclerose nuclear foi 2 ± 0,6 (variando de 1 a 4) e UDVA pré-operatória em logMAR foi de 0,4 ± 0,2 (variando de 0,1 a 1,3). A capsulotomia anterior foi completa em todos os pacientes e não precisou usar da pinça para cortar qualquer porção intacta. Incisões corneanas pós-operatórias não foram lineares, mostrando ainda algumas irregularidades. A facofragmentação a laser foi eficaz, com a divisão do núcleo em segmentos menores facilmente realizados antes da facoemulsificação. Após 1 mês de pós-operatório, UDVA em logMAR foi de 0,1 ± 0,1 (variando de 0,0 a 0,4) (P < 0,0001).Conclusão:Com o aumento do volume dos casos cirúrgicos e ganho de experiência, passos precisos da facoemulsificação são realizados com o pré-tratamento com o FSL, resultando em uma segura curva de aprendizagem.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged, 80 and over , Cataract Extraction , Laser Therapy , Learning Curve , Phacoemulsification , Retrospective Studies
6.
Arq. bras. oftalmol ; 77(2): 122-124, Mar-Apr/2014. graf
Article in English | LILACS | ID: lil-716262

ABSTRACT

This case report describes the production of an ultrathin endothelial donor corneal lamella using a femtosecond laser with low energy and a high frequency. In addition, we report its use in vivo in an eye with pseudophakic bullous keratopathy. The outcomes were observed 3 months after surgery in terms of the change in endothelial donor lamella and full cornea thickness (including pachymetric mapping), visual acuity, and endothelial cell count.


Este relato de caso mostra a confecção de uma lamela corneana doadora endotelial ultrafina com o uso de um laser de femtosegundo de baixa energia e alta taxa de repetição, e sua utilização in vivo em um paciente com ceratopatia bolhosa do pseudofácico. O resultado final foi observado quanto a evolução da espessura da lamela endotelial doadora e de toda a córnea (incluindo mapa paquimétrico), da acuidade visual, e da contagem endotelial ao final de 3 meses de pós-operatório.


Subject(s)
Female , Humans , Middle Aged , Corneal Diseases/surgery , Descemet Stripping Endothelial Keratoplasty/methods , Endothelium, Corneal/transplantation , Corneal Topography , Tomography, Optical Coherence , Visual Acuity
7.
Rev. bras. oftalmol ; 73(2): 71-74, Mar-Apr/2014. tab, graf
Article in English | LILACS | ID: lil-718435

ABSTRACT

Purpose: To evaluate the efficacy and reliability of a low-energy femtosecond laser with a high repetition rate for construction of deep anterior donor corneal lamellae. Methods: This was a prospective laboratory investigation. Twenty-five human corneal buttons were femtosecond laser cut to create thick anterior lamellae (diameter, 10mm; thickness, 500µm). The laser cuts were made using an LDV® femtosecond laser in a Ziemer® anterior chamber. To obtain a better edge, the lamellae were trephined with an 8mm trephine (Katena®). The central corneal thickness and the anterior lamellae were measured using a Mitutoyo® thickness gauge with an accuracy of 0.001mm. Results: The central thickness of the 25 corneas ranged from 500 to 705µm (mean, 584 ± 51µm). The thickness of the anterior lamellae ranged from 420 to 480µm (mean, 455 ± 12.7µm). The anterior lamellae diameters were 7.90 ± 0.1mm, and all laser cuts were round. The lamellar interfaces appeared regular by surgical microscopy. There were no cases of inter-lamellar adhesion. Conclusion: The LDV® femtosecond laser appears to be a safe and reliable instrument for cutting deep anterior lamellae from donor corneoscleral buttons. Minimal variation in donor lamellar depth with the laser will be useful for creating donor corneal tissue for deeper anterior lamellar keratoplasty or endothelial keratoplasty surgery or both from a single donor cornea. .


Objetivo: Avaliar a eficácia e segurança de um laser de femtossegundo de baixa energia e alta taxa de repetição para confecção de lamelas corneanas doadoras anteriores profundas. Métodos: Este é um estudo prospectivo de investigação laboratorial. Vinte e cinco botões corneanos foram cortados com laser de femtossegundo para criar lamelas corneanas doadoras anteriores profundas (diâmetro, 10mm; espessura, 500µm). O corte a laser foi realizado com femtosecond laser LDV® na câmara anterior artificial da Ziemer®. Para obter-se uma melhor borda, as lamelas foram trepanadas com um trépano de 8mm da Katena®. A paquimetria corneana central e as lamelas anteriores foram aferidas utilizando o paquímetro Mitutoyo®, com acurácia de 0.001mm. Resultados: A paquimetria central das 25 córneas variou de 500 a 705µm (média de 584 ± 51µm). A espessura das lamelas anteriores variou de 420 a 480µm (media de 455 ± 12.7µm). O diâmetro das lamelas corneanas doadoras foi 7.90 ± 0,1mm, sendo todos os cortes redondos. As interfaces lamelares apresentaram-se regular ao microscópio cirúrgico. Não houve casos de adesão interlamelar. Conclusão: O laser de femtossegundo LDV® mostrou-se seguro e eficaz para confeccionar lamelas corneanas doadoras a partir de botões córneo-esclerais. Mínima variação na espessura das lamelas doadoras confeccionadas com o laser será útil para criação de tecidos corneanos doadores para ceratoplastia lamelar anterior profunda ou ceratoplastia endoteliais, ou ambas, a partir de uma só córnea. .


Subject(s)
Humans , Tissue Donors , Corneal Transplantation/instrumentation , Corneal Transplantation/methods , Tissue and Organ Harvesting/methods , Lasers , Endothelium, Corneal/transplantation , Prospective Studies , Cornea/anatomy & histology , Corneal Topography , Dissection/instrumentation , Dissection/methods , Corneal Pachymetry/instrumentation , Corneal Pachymetry/methods
8.
Arq. bras. oftalmol ; 76(4): 226-228, jul.-ago. 2013. ilus, graf
Article in English | LILACS | ID: lil-686558

ABSTRACT

PURPOSE: To relate the outcomes of 7 eyes of 7 patients in which a dexamethasone 0.7 mg implant (Ozurdex®) was placed inside the capsule bag after phacoemulsification and intraocular lens (IOL) implantation and compare with the fellow eyes, that were operated by the same technique and received dexamethasone eyedrops in the post-operatory. METHODS: Report review of 7 eyes of 7 patients who received dexamethasone 0.7 mg implant after phacoemulsification and IOL, comparing them to the fellow eyes. All the patients underwent bilateral cataract surgery, with one month interval, by the same technique and by experienced surgeons, without complications. Post operatory medication consisted of moxifloxacin eye drops for all the 14 eyes and topic dexamethasone for the 7 eyes that did not received the implant. RESULTS: Nuclear cataract classification (according to LOCS III) was 3.28 ± 0.69 in the implant eye group and 3.14 ± 0.83 in the fellow eye group. Postoperative best spectacle correct visual acuity (BSCVA) was 0.85 ± 0.12 and 0.87 ± 0.13, respectively in the implant and fellow eye groups. The intraocular pressure remained stable and similar to the pre-operative measurements. Anterior chamber reaction and cornea edema were similar in both groups in the follow-up. Two of the four no sutured pellet migrated to the anterior chamber during the first post-operative week and had to be repositioned. Another no sutured pellet dislocated and remained partially inside the capsule bag. The 3 patients with IOL haptic-sutured pellet had no complications. CONCLUSIONS: In the present study, dexamethasone 0.7mg implant were effective in controlling the inflammation after phacoemulsification and IOL implantation, with no significant side effects.


OBJETIVOS: Relatar os resultados de 7 olhos de 7 pacientes em que foi realizado o implante de dexametasona 0,7 mg (Ozurdex®) no saco capsular após facoemulsificação e implante de lente intraocular (LIO) e comparar com os olhos contralaterais, que foram operados pela mesma técnica e receberam colírio de dexametasona no pós-operatório. MÉTODOS: Relato de casos de 7 olhos de 7 pacientes que receberam o implante de dexametasona 0,7 mg após facoemulsificação e implante de LIO, comparando-os com os olhos contralaterais. Todos os pacientes foram submetidos a cirurgia de catarata bilateral, com intervalo de um mês entre as cirurgias, pela mesma técnica, por cirurgiões experientes e sem complicações. No pós-operatório foi utilizado colírio de moxifloxacino em todos os 14 olhos e dexametasona tópica nos olhos que não receberam o implante. RESULTADOS: A classificação da catarata de acordo com o LOCS III foi de 3,28 ± 0,69 no grupo que recebeu o implante e 3,14 ± 0,83 no grupo de olhos contralateral. A acuidade visual com melhor correção foi de 0,85 ± 0,12 e 0,87 ± 0,13 respectivamente nos grupos com e sem implante. A pressão intraocular permaneceu estável e similar aos valores pré-operatórios. A reação de câmara anterior e o edema de córnea foram similares nos dois grupos. Dois dos 4 implantes sem sutura migraram para a câmara anterior durante a primeira semana de pós-operatório e necessitaram de reposicionamento. Outro implante sem sutura teve deslocamento e permaneceu parcialmente dentro do saco capsular. Os 3 pacientes com implante suturado não tiveram complicações. CONCLUSÃO: No presente estudo, o implante de dexametasona 0,7 mg foi efetivo no controle da inflamação intraocular após cirurgia de facoemulsificação e implante de LIO, sem efeitos colaterais significativos.


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Anti-Inflammatory Agents/administration & dosage , Dexamethasone/administration & dosage , Lens Implantation, Intraocular/methods , Phacoemulsification/methods , Postoperative Complications/prevention & control , Administration, Ophthalmic , Anterior Chamber/drug effects , Drug Implants , Postoperative Complications/drug therapy , Time Factors , Treatment Outcome , Visual Acuity
9.
Arq. bras. oftalmol ; 76(4): 240-243, jul.-ago. 2013. tab
Article in English | LILACS | ID: lil-686562

ABSTRACT

PURPOSE: To report the visual outcomes and complications of congenital cataract surgery with primary intraocular lens implantation in microphthalmic eyes of children younger than 4 years of age. METHODS:This retrospective interventional case series included 14 microphthalmic eyes from 10 children who underwent congenital cataract surgery with primary intraocular lens implantation younger than 4 years of age. Seven patients had bilateral cataracts (11 eyes met the study's inclusion criteria) and 3 patients had unilateral cataract. Patients' medical charts were reviewed to obtain information regarding the preoperative and postoperative ophthalmological examination. Main outcome measures were intraocular pressure (IOP), best-corrected visual acuity, and intraoperative and postoperative complications. RESULTS: Mean age at the time of surgery was 21.7 ± 2.9 months. Mean ocular axial length was 19.2 ± 0.9 mm. Mean preoperative IOP was 9.7 ± 1.7 mmHg and 10.3 ± 3.1 mmHg on final follow-up (P=0.18). There were no intraoperative complications. Two (15.4%) eyes developed secondary visual axis opacification, of which only one needed to be reoperated due to significantly decreased vision (0.5 logMAR). Preoperative and postoperative best-corrected visual acuity was 2.09 ± 0.97 logMAR and 0.38 ± 0.08 logMAR in bilateral cases and 1.83 ± 1.04 logMAR and 0.42 ± 0.13 logMAR in unilateral cases, respectively. CONCLUSION: Primary intraocular lens implantation in congenital cataract surgery in microphthalmic eyes resulted in a significant best-corrected visual acuity improvement with no intraoperative complications and minimal postoperative complications.


OBJETIVOS: Relatar os resultados visuais e as complicações da cirurgia de catarata congênita com implante primário de lente intraocular em olhos microftálmicos de crianças menores de 4 anos. MÉTODOS: Esta série de casos retrospectiva incluiu 14 olhos microftálmicos de 10 crianças menores de 4 anos que foram submetidas à cirurgia de catarata congênita com implante primário de lente intraocular. Sete pacientes tinham catarata bilateral (11 foram incluídos no estudo) e 3 tinham catarata unilateral. Os prontuários dos pacientes foram revisados para se obter informação sobre o exame oftalmológico pré- e pós-operatório. As principais variáveis analisadas foram pressão intraocular, acuidade visual com melhor correção e complicações intra- e pós-operatórias. RESULTADOS: A média da idade dos pacientes na época da cirurgia foi de 21,7 ± 2,9 meses. O diâmetro antero-posterior médio foi de 19,2 ± 0,9 mm. A pressão intraocular média pré-operatória foi 9,7 ± 1,7 mmHg e 10,3 ± 3,1 mmHg no último exame de acompanhamento pós-operatório (P=0,18). Não houve complicações intraoperatórias. Dois (15,4%) olhos desenvolveram opacificação secundária do eixo visual, dos quais um foi reoperado devido à baixa visual significativa (0,5 logMAR). AV pré- e pós-operatórias foram 2,09 ± 0,97 logMAR e 0,38 ± 0,08 logMAR em casos de catarata congênita bilateral e 1,83 ± 1,04 logMAR e 0,42 ± 0,13 logMAR em casos unilaterais, respectivamente. CONCLUSÃO: O implante primário de lente intraocular em cirurgia de catarata congênita em olhos microftálmicos resultou em uma melhora significativa da acuidade visual com nenhuma complicação intraoperatória e com pouca complicação no pós-operatório.


Subject(s)
Female , Humans , Infant , Male , Cataract Extraction/methods , Cataract/congenital , Lens Implantation, Intraocular/methods , Microphthalmos/complications , Cataract/complications , Follow-Up Studies , Intraocular Pressure , Intraoperative Complications , Postoperative Complications , Retrospective Studies , Time Factors , Treatment Outcome , Visual Acuity
10.
Arq. bras. oftalmol ; 75(6): 412-414, nov.-dez. 2012. ilus
Article in Portuguese | LILACS | ID: lil-675624

ABSTRACT

OBJETIVO: Avaliar a reconstituição do ducto nasolacrimal com o uso de radiofrequência para restabelecimento do fluxo lacrimal nos casos de obstrução da via lacrimal excretora. MÉTODOS: O procedimento foi realizado em 16 olhos de 16 pacientes (13 femininos e 3 masculinos) pelo mesmo cirurgião, utilizando aparelho de radiofrequência monopolar de 450 kHz e 150 W de potência, com anestesia local sob sedação. Os critérios de inclusão foram obstrução baixa da via lacrimal (confirmada por dacriocistografia) e idade superior a 18 anos. Os critérios de exclusão foram trauma prévio, dacriocistite aguda, fístula cutânea, mucocele, cirurgia prévia da via lacrimal e uso de marca-passo cardíaco. RESULTADOS: O seguimento mínimo foi de 120 dias, os pacientes realizaram retornos ambulatoriais para avaliação clínica (presença de epífora, secreção, refluxo à expressão do saco lacrimal, posicionamento do tubo de silicone) e teste de Milder. Aos 90 dias de pós-operatório, 13 pacientes apresentavam irrigação positiva (81,25%) com desobstrução do ducto nasolacrimal e 3 casos (18,75%) de insucesso com irrigação impossibilitada (sem passagem para cavidade nasal). CONCLUSÃO: A reconstituição do ducto nasolacrimal com radiofrequência mostrou-se eficaz no tratamento da obstrução da via lacrimal excretora.


PURPOSE: To evaluate the nasolacrimal duct reconstitution with radio frequency for restoration of lacrimal flow in cases of nasolacrimal duct obstruction. METHODS: The procedure was carried out in 16 eyes of 16 patients (13 women and 3 men) by the same surgeon, with monopolar high-frequency device at 450 kHz and 150 W, with local anesthesia under sedation. Inclusion criteria were lower lacrimal system obstruction (confirmed by dacryocystogram) and age over 18 years old. Exclusion criteria were previous trauma, acute dacryocystitis, cutaneous fistula, mucocele, previous lacrimal surgery and cardiac pacemaker. RESULTS: Patients were followed for at least 120 days, patients were clinically evaluated at outpatient clinics for the presence of secretion, epiphora, reflux at compression of the lacrimal sac, placement of silicone tube and Milder test. At the 90-day postoperative visit, 13 patients had positive irrigation (81.25%) with clearance of lacrimal duct and 3 cases (18.75%) presented irrigation failure. CONCLUSION: Nasolacrimal duct reconstitution with radio frequency was effective in treating nasolacrimal duct obstruction.


Subject(s)
Adolescent , Female , Humans , Male , Dacryocystorhinostomy/methods , Lacrimal Duct Obstruction/surgery , Nasolacrimal Duct/surgery , Catheter Ablation/methods , Lacrimal Duct Obstruction/radiotherapy , Nasolacrimal Duct/radiation effects , Treatment Outcome
11.
Rev. bras. oftalmol ; 71(4): 260-271, jul.-ago. 2012. ilus, tab
Article in Portuguese | LILACS | ID: lil-650662

ABSTRACT

Os implantes em olhos fácicos apresentam-se como uma opção para a correção de altas ametropias. De acordo com sua localização podem ser classificados como de câmara anterior ou posterior, sendo que os primeiros subdividem-se em fixação iriana ou de suporte angular. Além da correção da miopia, as lentes de fixação iriana apresentam modelos para hipermétropes e astigmatas. Várias modificações no desenho das lentes foram propostas nas últimas décadas com a finalidade de reduzir complicações tardias, como a perda endotelial progressiva. Cuidados no intraoperatório devem ser tomados de forma a diminuir a perda endotelial aguda relacionada ao trauma. Avanços nos métodos de triagem pré-operatória também melhoraram a segurança do procedimento. A estimativa do poder dióptrico é baseada nos cálculos de Van der Heijde, sendo dependente da profundidade de câmara anterior, do equivalente esférico da refração e da média ceratométrica. Resultados a longo prazo demonstram a eficácia, previsibilidade e segurança do procedimento. Dependendo do modelo, além da possibilidade de perda endotelial, outras possíveis complicações incluem: irite, dispersão pigmentar, atrofia de íris, ovalização pupilar, rotação, descentração ou deslocamento da lente, hipertensão ocular e bloqueio pupilar. Modelos dobráveis atualmente disponíveis vêm apresentado resultados bastante promissores com redução da taxa de complicações.


The phakic intraocular lenses (pIOLs) are a good option for the correction of high refractive errors. According to their anatomical position there are two types of pIOLs: anterior or posterior chamber. The anterior chamber pIOL may be iris-fixated or angle-supported. The iris-fixated pIOLs are available not only for myopia correction, but also for hyperopia and astigmatism. During the last decades many modifications on the pIOLs designs were proposed in order to reduce late complications, such as progressive endothelial cell loss. Acute endothelial cell trauma related to the surgical procedure may be minimized with proper intraoperative care. Advances in the preoperative screening methods have improved the safety of the procedure. Estimation of the pIOL power is based on the van der Heijde calculations and is dependent on the anterior chamber depth, the spherical equivalent and the mean keratometric values. Long-term results show the efficacy, predictability and safety of the procedure. According to the type of the pIOL, complications other than endothelial cell loss include iritis, pigment dispersion, iris atrophy, pupil ovalization, pIOL rotation, decentration or dislocation, intraocular pressure elevation and pupillary block glaucoma. Foldable models actually available show promising results with lower complication rate.


Subject(s)
Humans , Anterior Chamber , Intraoperative Complications , Lens Implantation, Intraocular/adverse effects , Phakic Intraocular Lenses , Postoperative Complications , Refractive Errors
12.
Arq. neuropsiquiatr ; 69(5): 809-813, Oct. 2011. tab
Article in English | LILACS | ID: lil-604223

ABSTRACT

OBJECTIVE: To assess the visual quality of life in patients with multiple sclerosis (MS), and to observe whether this parameter could be correlated to the findings of the ophthalmologic examination. METHOD: The translated and validated 25-Item National Eye Institute Visual Function Questionnaire (VFQ-25) was used to assess the visual quality of life. Clinical data on MS, visual acuity, visual fields, optic coherence tomography (OCT) and disc cupping were used for assessing correlation with VFQ-25. RESULTS: The mean VFQ-25 value was 78.6±18.2 percent in 27 patients. VFQ-25 did not correlate with patients' ages, with disability (EDSS), disease duration or medication use. Visual acuity showed a relatively poor (<60 percent) correlation to VFQ-25, while no correlation could be established between visual fields, OCT and disc cupping with VFQ-25. CONCLUSION: MS patients present several alterations in their eyes and sight that cannot be assessed by isolated measures. Ophthalmological examination of these patients must include many parameters not usually used in standard ophthalmologic consultations.


OBJETIVO: Avaliar a qualidade de vida visual de pacientes com esclerose múltipla (EM) e observar se este parâmetro pode ser relacionado aos achados do exame oftalmológico. MÉTODO: O questionário traduzido e validado 25-Item National Eye Institute Visual Function Questionnaire (VFQ-25) foi utilizado para avaliar a qualidade de vida visual. Dados clínicos da EM, acuidade visual, campo visual, tomografia de coerência óptica (OCT) e escavação do disco foram utilizados para correlação com VFQ-25. RESULTADOS: A média do VFQ-25 foi 78,6±18,2 por cento em 27 pacientes. VFQ-25 não se correlacionou com a idade dos pacientes, com a incapacidade (EDSS), duração da doença ou medicação em uso. A acuidade visual mostrou uma correlação relativamente pobre (<60 por cento) com VFQ-25, enquanto não foi observada nenhuma correlação entre campo visual, OCT e escavação de disco com VFQ-25. CONCLUSÃO: Pacientes com EM apresentam diversas alterações oculares e na visão que não podem ser avaliadas por medidas isoladas. O exame oftalmológico destes pacientes deve incluir parâmetros que não são habitualmente utilizados em consultas oftalmológicas padronizadas.


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Multiple Sclerosis/complications , Quality of Life , Sickness Impact Profile , Vision Disorders/etiology , Brazil , Multiple Sclerosis/psychology , Surveys and Questionnaires , Tomography, Optical Coherence , Visual Acuity , Vision Disorders/psychology
13.
Arq. bras. oftalmol ; 74(1): 13-16, Jan.-Feb. 2011. graf, tab
Article in English | LILACS | ID: lil-589931

ABSTRACT

PURPOSE: To evaluate and compare corneal hysteresis (CH) and corneal resistance factor (CRF) in healthy eyes with a central corneal thickness (CCT) < 505 µm with CH and CRF in gender-, age-, and CCT-matched keratoconus cases, and to estimate the sensitivity and specificity of these parameters for discriminating between the two groups. METHODS: Prospective, comparative case series. In total 46 eyes from 30 healthy patients with CCT < 505 µm, and 42 eyes from 30 CCT-, gender- and age-matched keratoconus cases were enrolled. Biomechanical metrics (CH and CRF) were measured using the Ocular Response Analyzer (ORA) and then compared. A receiver operating characteristic (ROC) curve was used to identify cut-off points to maximize the sensitivity and specificity for discriminating between the groups. RESULTS: The CCT was 485.96 ± 17.61 µm (range, 438 - 505) in healthy thin corneas and 483.64 ± 16.19 µm (range, 452 - 505) in keratoconus; p=0.5225. CH was 8.63 ± 1.23 mmHg (range, 5.95 - 12.2) and 8.07 ± 1.17 mmHg (range, 4.9 - 9.85), respectively; p=0.0312. CRF was 8.43 ± 1.29 mmHg (range, 5.45 - 11.10) and 7.22 ± 1.34 mmHg (range, 4.7 - 9.45), respectively; p<0.001. ROC curve analysis showed a poor overall predictive accuracy of CH (cut-off, 8.95 mmHg; sensitivity, 63 percent; specificity, 23.8 percent; test accuracy, 44.30 percent) and CRF (cut-off, 7.4 mmHg; sensitivity, 28.3 percent; specificity, 40.5 percent; test accuracy, 34.12 percent) for detecting keratoconus in the eyes studied. CONCLUSION: CH and CRF were statistically lower in keratoconus than in healthy thin corneas. However, CH and CRF offered very low sensitivity and specificity for discriminating the groups.


OBJETIVO: Avaliar e comparar a histerese corneana (CH) e o fator de resistência corneano (CRF) em olhos saudáveis com espessura corneana central (CCT) < 505 µm com os resultados de CH e CRF em pacientes com ceratocone pareados por sexo, idade e CCT, além de estimar a sensibilidade e especificidade destes parâmetros na diferenciação dos grupos. MÉTODOS: Estudo prospectivo, do tipo série de casos comparativa. No total, 46 olhos de 30 pacientes saudáveis com CCT < 505 µm, e 42 olhos de 30 pacientes com ceratocone pareados por sexo, idade e CCT foram incluídos. Os parâmetros biomecânicos (CH e CRF) foram obtidos através do equipamento Ocular Response Analyzer (ORA) e depois comparados. Curvas ROC (Receiver operating characteristic) foram utilizadas para identificar o melhor valor de corte que apresentasse a maior sensibilidade e especificidade na discriminação entre ceratocone e córneas finas saudáveis para cada dado estudado. RESULTADOS: A CCT encontrada foi 485,96 ± 17,61 µm (de 438 a 505) no grupo de córneas finas saudáveis e 483.64 ± 16,19 µm (de 452 a 505) no grupo ceratocone; p=0,5225. CH 8,63 ± 1,23 mmHg (de 5,95 a 12,2) e 8,07 ± 1,17 mmHg (de 4,9 a 9,85), respectivamente; p=0,0312. CRF 8,43 ± 1,29 mmHg (de 5,45 a 11,10) e 7,22 ± 1,34 mmHg (de 4,7 a 9,45), respectivamente; p<0,001. Análise das curvas ROC mostrou baixa acurácia na diferenciação das córneas finas saudáveis daquelas com ceratocone tanto para CH (ponto de corte, 8,95 mmHg; sensibilidade, 63 por cento; especificidade, 23,8 por cento; acurácia, 44,30 por cento) quanto para CRF (ponto de corte, 7,4 mmHg; sensibilidade, 28,3 por cento; especificidade, 40,5 por cento; acurácia, 34,12 por cento). CONCLUSÃO: Dados fornecidos pelo ORA (CH e CRF) mostraram-se estatisticamente mais baixos em pacientes com ceratocone quando comparados com córneas finas de indivíduos saudáveis. No entanto, os dois parâmetros biomecânicos estudados apresentaram sensibilidade e especificidade muito baixas na diferenciação dos grupos.


Subject(s)
Adult , Female , Humans , Male , Cornea/physiology , Elastic Tissue/physiology , Elasticity/physiology , Keratoconus/physiopathology , Biomechanical Phenomena , Case-Control Studies , Corneal Topography , Cornea/anatomy & histology , Keratoconus/diagnosis , Keratoconus/pathology , Prospective Studies , ROC Curve , Sensitivity and Specificity
14.
Arq. bras. oftalmol ; 73(4): 333-337, July-Aug. 2010. ilus, tab
Article in English | LILACS | ID: lil-560605

ABSTRACT

PURPOSE: To evaluate the sensitivity, specificity, and test accuracy of corneal biomechanical metrics and anterior segment data in differentiating keratoconus from healthy corneas. METHODS: Comparative case series. Patients with and without keratoconus (gender and age-matched) were submitted for complete eye examinations including corneal hysteresis (CH) and corneal resistance factor (CRF) as measured by the Ocular Response Analyzer and anterior segment data as gathered through Pentacam assessments. The anterior segment data measurement included average central keratometric readings (K-Ave), corneal astigmatism (CA), central corneal thickness (CCT), anterior chamber depth (AC depth) and corneal volume (CV). All parameters were assessed, compared and analyzed. A receiver operating characteristic (ROC) curve was used to identify the best cutoff point by which to maximize the sensitivity and specificity of discriminating keratoconus from normal corneas for each data category. RESULTS: Seventy seven eyes from forty three patients (24 male, 19 female) with keratoconus and eighty six eyes from forty three (24 male, 19 female) healthy controls were enrolled. ROC curve analysis showed poor overall predictive accuracy for all studied parameters in differentiating keratoconus from normal corneas. The highest sensitivity (79.2 percent) was obtained for both AC depth and CH (cutoff points 3.22 mm and 9.39 mmHg respectively). The best specificity (89.5 percent) and test accuracy (80.34 percent) were obtained for CA (cutoff point of 2.2 D). CONCLUSION: When considered together, studied parameters showed statistical differences between groups. However, when considered independently they presented low sensitivity, specificity and test accuracy in differentiating keratoconus from healthy corneas.


OBJETIVO: Avaliar a sensibilidade, especificidade e acurácia de parâmetros biomecânicos e anatômicos do segmento anterior isolados na diferenciação de córneas saudáveis e com ceratocone. MÉTODOS: Estudo tipo série de casos comparativa. Pacientes com ceratocone e controles saudáveis foram pareados (idade e sexo) e submetidos a exame oftalmológico completo, incluindo avaliação biomecânica (ORA) e tomográfica (Pentacam). Ceratometria central média, astigmatismo corneano, espessura corneana central, profundidade da câmara anterior, volume corneano, CH e CRF foram estabelecidos, avaliados e comparados. Curvas ROC (Receiver operating characteristic) foram utilizadas para identificar o melhor valor de corte que apresentasse a maior sensibilidade e especificidade na discriminação entre ceratocone e córneas saudáveis para cada dado estudado. RESULTADOS: Setenta e sete olhos de 43 pacientes com ceratocone (24 homens e 19 mulheres) e 86 olhos de pacientes saudáveis (24 homens e 19 mulheres) foram incluídos no estudo. Curvas ROC mostraram baixa acurácia na predição do diagnóstico de ceratocone em todos os parâmetros isolados estudados. Maior sensibilidade encontrada foi 79,2 por cento para profundidade da câmara anterior e CH (ponto de corte 3,22mm e 9,39mmHg respectivamente); maior especificidade e acurácia foram encontradas na análise do astigmatismo corneano (ponto de corte 2,2 D; 89,5 por cento e 80,34 por cento respectivamente). CONCLUSÃO: Todos os parâmetros estudados mostraram diferença estatisticamente significativa entre os grupos. No entanto, quando considerados isoladamente apresentaram baixas sensibilidade, especificidade e acurácia na diferenciação entre ceratocone e córneas saudáveis.


Subject(s)
Adolescent , Adult , Aged , Female , Humans , Male , Middle Aged , Young Adult , Anterior Chamber/anatomy & histology , Cornea/anatomy & histology , Keratoconus/diagnosis , Anterior Chamber/pathology , Biomechanical Phenomena , Case-Control Studies , Cornea/pathology , Corneal Topography/methods , ROC Curve , Statistics, Nonparametric
15.
Arq. bras. oftalmol ; 72(5): 687-693, set.-out. 2009. graf, tab
Article in Portuguese | LILACS | ID: lil-534193

ABSTRACT

OBJETIVO: Comparar a correção das aberrações oculares nos retratamentos de LASIK personalizado e convencional. MÉTODOS: Foi realizado um estudo prospectivo, randomizado, de 74 olhos de 37 pacientes submetidos ao retratamento de LASIK para correção de miopia e astigmatismo. Cada paciente foi submetido ao retratamento de LASIK personalizado Zyoptix (Bausch & Lomb) em um olho e convencional Planoscan (Bausch & Lomb) no olho contralateral. Foi comparada a correção das aberrações oculares nos retratamentos personalizado e convencional. RESULTADOS: No sexto mês pós-operatório, os olhos submetidos ao retratamento Zyoptix apresentaram diminuição estatisticamente significativa do defocus, astigmatismo, coma, aberração esférica, segunda ordem, terceira ordem, alta ordem e aberrações totais. Os olhos submetidos ao retratamento Planoscan apresentaram diminuição estatisticamente significativa do defocus, segunda ordem e aberrações totais. CONCLUSÕES: O retratamento personalizado foi superior ao retratamento convencional para a correção das aberrações oculares de baixa e alta ordens.


PURPOSE: To compare the correction of ocular aberrations between custom and standard LASIK retreatment. METHODS: Prospective, randomized trial with paired eye control of 74 eyes from 37 patients who underwent LASIK retreatment. Each patient underwent retreatment using Zyoptix LASIK (Bausch & Lomb) in 1 eye and Planoscan LASIK (Bausch & Lomb) in the fellow eye. Correction of ocular aberrations was compared between custom and standard LASIK retreatments. RESULTS: At 6 months, there was a statistically significant reduction in defocus, astigmatism, coma, spherical aberration, second, third, higher-order and total aberration in Zyoptix eyes. There was a statistically significant reduction in defocus, second-order and total aberration in Planoscan eyes. CONCLUSIONS: Custom retreatment was statistically superior than standard retreatment for correction of lower and higher ocular aberrations.


Subject(s)
Humans , Astigmatism/surgery , Keratomileusis, Laser In Situ/methods , Myopia/surgery , Astigmatism/physiopathology , Myopia/physiopathology , Prospective Studies , Retreatment , Statistics, Nonparametric , Time Factors
16.
Arq. bras. oftalmol ; 72(4): 519-525, July-Aug. 2009. graf, tab
Article in Portuguese | LILACS | ID: lil-528019

ABSTRACT

OBJETIVO: Comparar os resultados obtidos após o Lasik personalizado utilizando duas plataformas diferentes. MÉTODOS: Estudo prospectivo, randomizado com 50 pacientes míopes submetidos a cirurgia refrativa em ambos os olhos. Foram selecionados para o estudo, pacientes com equivalente esférico semelhante entre os olhos. Todos foram submetidos a Lasik bilateral e simultâneo, sendo que um olho foi operado pela plataforma CustomCornea® e o outro pela Zyoptix®. Acuidade visual sem e com correção, refração dinâmica e estática, medida das aberrações oculares, teste de sensibilidade ao contraste foram realizados no período pré-operatório e pós-operatório de 1, 3 e 6 meses. RESULTADOS: No período pré-operatório a média do equivalente esférico era de -3,29 ± 1,56 D no grupo CustomCornea® e de -3,22 ± 1,50 D no Zyoptix® (p=0,267). No sexto mês de pós-operatório, a média do equivalente esférico no grupo CustomCornea® era de -0,077 ± 0,23 D e -0,282 ± 0,30 D no Zyoptix® (p<0,001*). Acuidade visual sem correção > 20/20 foi alcançada em 86 por cento dos olhos no grupo CustomCornea® e 70 por cento no grupo Zyoptix® (p=0,094). Nenhum paciente perdeu duas ou mais linhas da melhor acuidade visual corrigida. Cem por cento dos olhos CustomCornea® e 88 por cento dos Zyoptix® ficaram entre ± 0,50 D da emetropia (p=0,014*). Melhora da sensibilidade ao contraste em todas as frequências espaciais testadas foi observada em ambos os grupos. A aberração esférica apresentou aumento em ambos os grupos, porém este foi estatisticamente maior na plataforma Zyoptix® (p<0,001). CONCLUSÃO: Não foram observadas diferenças entre os grupos quanto à eficácia e segurança. O tratamento com a plataforma Zyoptix® consumiu menor quantidade de estroma. Melhor previsibilidade da correção cirúrgica foi obtida pelo grupo CustomCornea®, bem como menor indução de aberração esférica.


PURPOSE: To compare the visual and clinical outcomes of Wavefront-guided laser in situ keratomileusis (Lasik) with Alcon CustomCornea® and Zyoptix® systems. METHODS: A prospective, randomized, masked and bilateral study was conducted. Fifty patients with preoperative spherical equivalent ranging from -1.00 to -6.50 D were enrolled for customized ablation in both eyes. All of them were submitted to Lasik CustomCornea® treatment in one eye and Zyoptix® in the other eye. Uncorrected visual acuity, best correct visual acuity (BCVA), manifest refraction, wavefront measurements, and contrast sensitivity testing were performed preoperatively and postoperatively at 1, 3 and 6 months. RESULTS: Preoperatively manifest refractive spherical equivalent was -3.29 ± 1.56 D in the CustomCornea® group and -3.22 ± 1.50 D in the Zyoptix® group. At 6 months, 86 percent of CustomCornea® eyes and 70 percent of Zyoptix® eyes had UCVA > 20/20. One hundred percent of the CustomCornea® group and 88 percent of the eyes in the Zyoptix® were within 0.50 D of emmetropia. In both groups, the contrast sensitivity improved. Spherical aberration increased in both groups, with the CustomCornea® group showing lower levels (p<0,001). CONCLUSION: There were no differences between the systems according to safety and effectiveness. The Zyoptix® platform showed greater spherical aberration.


Subject(s)
Adult , Humans , Young Adult , Keratomileusis, Laser In Situ/methods , Myopia/surgery , Visual Acuity , Prospective Studies , Severity of Illness Index , Treatment Outcome , Young Adult
17.
Arq. bras. oftalmol ; 71(6): 841-846, nov.-dez. 2008. graf, tab
Article in Portuguese | LILACS | ID: lil-503451

ABSTRACT

OBJETIVO: Avaliar a qualidade visual após retratamento personalizado e retratamento convencional em olhos submetidos a LASIK primário convencional. MÉTODOS: Foi realizado estudo prospectivo de 74 olhos submetidos ao retratamento de LASIK para correção de miopia e astigmatismo. Cada paciente foi submetido ao retratamento de LASIK com ablação personalizada (Zyoptix, Bausch & Lomb) em um olho e ablação convencional (Planoscan, Bausch & Lomb) no olho contralateral. Foram comparados os resultados do teste de ofuscamento e da sensibilidade ao contraste durante o acompanhamento de seis meses. RESULTADOS: Os olhos do grupo Zyoptix apresentaram melhores resultados no teste de ofuscamento e na sensibilidade ao contraste do que o olho contralateral, quando se compararam os resultados. CONCLUSÕES: O retratamento personalizado resultou em melhor qualidade visual pós-operatória do que o retratamento convencional de LASIK primário convencional.


PURPOSE: To evaluate visual quality after wavefront-guided LASIK versus standard LASIK in retreatment of primary LASIK for myopia and myopic astigmatism. METHODS: A prospective study was performed with paired eye control of 74 eyes with LASIK retreatment. Each patient underwent retreatment using custom ablation (Zyoptix, Bausch & Lomb) in 1 eye and standard ablation LASIK (PlanoScan, Bausch & Lomb) in the contralateral eye. A complete ophthalmologic examination was performed, including evaluation of glare test and contrast sensitivity test, with a follow-up of 6 months. RESULTS: Zyoptix eyes showed better results of glare test and contrast sensitivity test than the contralateral eyes. CONCLUSIONS: Wavefront-guided LASIK produces better visual quality than standard LASIK in the retreatment of refractive errors after primary LASIK.


Subject(s)
Humans , Astigmatism/surgery , Keratomileusis, Laser In Situ/methods , Myopia/surgery , Visual Acuity/physiology , Astigmatism/physiopathology , Contrast Sensitivity/physiology , Follow-Up Studies , Glare , Myopia/physiopathology , Prospective Studies , Retreatment , Statistics, Nonparametric , Treatment Outcome
18.
Arq. bras. oftalmol ; 71(5): 651-659, set.-out. 2008. ilus, graf, tab
Article in Portuguese | LILACS | ID: lil-497215

ABSTRACT

OBJETIVO: Avaliar os resultados do retratamento personalizado (Zyoptix, Bausch & Lomb) e do retratamento convencional (Planoscan, Bausch & Lomb) em olhos submetidos a LASIK primário convencional. MÉTODOS: Foi realizado estudo prospectivo, randomizado, de 74 olhos de 37 pacientes submetidos a retratamento de LASIK para correção de miopia e astigmatismo. Cada paciente foi submetido a retratamento de LASIK com ablação personalizada em um olho e ablação convencional no olho contralateral. Foram comparadas a acuidade visual de alto contraste e refração manifesta, com acompanhamento de seis meses. RESULTADOS: Os retratamentos personalizados de LASIK (Zyoptix) e os retratamentos convencionais de LASIK (Planoscan) apresentaram valores estatisticamente similares para a acuidade visual, ganho/perda de linhas da melhor acuidade visual corrigida, índices de segurança e eficácia e porcentagem de olhos com equivalente esférico (EE) entre ± 0,50 D e 1,00 D no período pós-operatório de seis meses. Houve diferença significativa para os valores do componente esférico e do equivalente esférico nos períodos pós-operatórios de uma semana, um, três e seis meses entre os grupos Zyoptix e Planoscan. Os olhos do grupo Zyoptix apresentaram valores mais hipermétropes do que os olhos do grupo Planoscan. A previsibilidade da correção do equivalente esférico no grupo Zyoptix foi superior à do grupo Planoscan. CONCLUSÕES: A ablação personalizada proporciona melhores resultados refracionais do que a ablação convencional para os retratamentos de LASIK convencional. A medida da acuidade visual de alto contraste não é parâmetro sensível para evidenciar a melhor técnica cirúrgica.


PURPOSE: To evaluate refractive outcomes of wavefront-guided LASIK (Zyoptix, Bausch & Lomb) versus standard LASIK (PlanoScan, Bausch & Lomb) in retreatment of primary LASIK for myopia and myopic astigmatism. METHODS: A prospective, randomized trial with paired eye control of 74 eyes from 37 patients who underwent LASIK retreatment was performed. Each patient underwent retreatment using Zyoptix LASIK in 1 eye and Planoscan LASIK in the contralateral eye. A complete ophthalmologic examination was performed, including evaluation of high contrast visual acuity and manifest refraction, with a follow-up of 6 months. RESULTS: Both Zyoptix and Planoscan groups had similar values of high contrast visual acuity, gain and loss of best spectacle-corrected visual acuity, safety and efficacy indexes, percentage of eyes with spherical equivalent within ± 0,50 D and ± 1,00 D in the postoperative period of 6 months. In the Zyoptix group, the values of spherical component and spherical equivalent of manifest refraction were more hyperopic than in the Planoscan group in the postoperative periods of 1 week, 1, 3 and 6 months. The predictability of spherical equivalent correction was better for the Zyoptix group than for the Planoscan group at 6 months. CONCLUSIONS: Wavefront-guided LASIK with Zyoptix produces superior refractive outcomes than standard LASIK with Planoscan in retreatment of refractive errors after primary LASIK. High contrast visual acuity measures are not sensitive in showing the best technique.


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Young Adult , Astigmatism/surgery , Keratomileusis, Laser In Situ/methods , Myopia/surgery , Visual Acuity , Prospective Studies , Reoperation , Treatment Outcome , Young Adult
19.
Arq. bras. oftalmol ; 70(1): 45-50, jan.-fev. 2007. ilus
Article in Portuguese | LILACS | ID: lil-453127

ABSTRACT

OBJETIVO: Descrever os achados da microscopia confocal in vivo em pacientes nos diversos estágios de ceratopatia induzida por amiodarona, e correlacionar o estadiamento biomicroscópico com o estadiamento confocal. MÉTODOS: Vinte olhos de 10 pacientes (6 homens e 4 mulheres) em tratamento com amiodarona, que apresentavam ceratopatia induzida pela droga, foram selecionados para o estudo, com a microscopia confocal (MC). RESULTADOS: A média de idade foi 58 ± 6,2 anos (50-66 anos) e o tempo de uso da droga foi de 6 ± 3,2 anos (2-11 anos). Todos pacientes tinham acuidade visual com correção melhor ou igual a 20/40. A biomicroscopia evidenciou ceratopatia por amiodarona: dois pacientes no estágio 1, quatro no estágio 2 e quatro no estágio 3. Todas as córneas apresentaram inclusões intracelulares brilhantes e de alta refletividade na camada epitelial basal. A partir dos estágios 2 e 3, foram encontrados microdepósitos em todas camadas corneanas. Foram observados afilamento e aumento da tortuosidade dos nervos corneanos nos estágios 2 e 3 da ceratopatia. A contagem endotelial média foi de 2.524 ± 150,3 células/mm². CONCLUSÃO: O epitélio basal foi o mais acometido nos diferentes estágios da ceratopatia. Nos pacientes do estágio 1 a biomicroscopia, os microdepósitos subepiteliais são restritos ao epitélio superficial e basal, ao passo que nos pacientes dos estágios 2 e 3, os microdepósitos afetam todas camadas corneanas. A medida que a ceratopatia avança, os nervos corneanos ficam mais afilados e tortuosos.


PURPOSE: To describe in vivo confocal microscopy findings in patients with different stages of amiodarone-induced keratopathy, and correlate biomicroscopy stages with confocal stages. METHODS: Twenty eyes of 10 patients (6 men and 4 women), who receive treatment with amiodarone were selected for the study with confocal microscopy (MC). RESULTS: The average age was 58 ± 6.2 years (50-66 years) and time of use of the drug was 6 ± 3.2 years (2-11 years). All patients have best correct visual acuity ³ 20/40. There were two patients in stage 1, 4 patients in stage 2 and 4 in stage 3 of induced keratopathy. All corneas presented brilliant intracellular inclusions with high reflectivity in the basal epithelium layer. Patients in stage 2 and 3 have all corneal layers affected. There are thinning and increase of tortuosity of corneal nerves in patients in stage 2 and 3. The endothelial count was 2,524 ± 150,3 cell/mm². CONCLUSION: The basal epithelium was most affected in any of the keratopathy stages. In stage 1 patients only the superficial and basal epithelium are affected, while patients in stages 2 and 3 have all corneal layers affected. With the advance of keratophaty the corneal nerves became thinner and tortuous.


Subject(s)
Humans , Male , Female , Middle Aged , Amiodarone/adverse effects , Anti-Arrhythmia Agents/adverse effects , Corneal Diseases/chemically induced , Corneal Diseases/pathology , Microscopy, Acoustic , Microscopy, Confocal , Severity of Illness Index
20.
An. Fac. Med. Univ. Fed. Pernamb ; 52(2): 95-99, 2007. tab
Article in Portuguese | LILACS | ID: lil-495351

ABSTRACT

Objetivo: Avaliar os efeitos do hábito de fumar e beber, na saúde visual, foram avaliados 434 indivíduos, residentes em Salgueiro - Sertão de Pernambuco, de ambos os sexos, com idade igual ou superior a 60 anos. Métodos: Os voluntários foram entrevistados, a fim de investigar antecedentes pessoais e familiares de doenças crônicas não transmissíveis (particularmente hipertensão arterial e diabetes); além de hábitos como fumar e beber bebidas alcoólicas. Considerou-se baixa a acuidade visual os pacientes com visão apresentada pior que 20/60 no melhor olho, utilizando os critérios do Código Internacional de Doenças - CID 10. Resultados/Conclusão: Pode-se concluir que foi encontrada forte associação entre o hábito de fumar e a presença de baixa acuidade visual, o que reforça os dados que relacionam o tabagismo como fator predisponente ao desenvolvimento de DMRI e catarata, e consequentemente a deficiência visual.


Subject(s)
Humans , Male , Female , Aged , Alcohol Drinking , Aged , Impacts of Polution on Health , Eye Diseases/epidemiology , Unified Health System , Tobacco Use Disorder , Vision, Ocular , Vision, Low , Cross-Sectional Studies , Eye Infections
SELECTION OF CITATIONS
SEARCH DETAIL